logo
logo

This document provides an overview of the specifications and factory default settings specific to your Proteus WeldSaverâ„¢ product. Please retain this sheet for future reference.

Additional product information is available on the Proteus Industries website at:


PRODUCT INFORMATION


Model Number

9WSEV13N-1-MR1

Serial Number/MAC ID

00-23-92-00-C9-ED

Sale Order Number

143539

Product Series

WeldSaver 5

Control Interface

Ethernet/IP

Firmware Revision

3.9.1


CONTROL PARAMETER SETTINGS



Flow Warning

3 GPM

Flow Fault

2 GPM

Slow Leak Difference

1 GPM

Slow Leak Delay

1000 ms

Stabilization Delay

4s

Leak Response

Normal


FLOW SENSOR CALIBRATION


Inlet Multiplier

528

Inlet Divisor

10000

Inlet Offset

0

Outlet Multiplier

504

Outlet Divisor

10000

Outlet Offset

5


NETWORK SETTINGS


IP Address

192.168.2.4

Netmask

255.255.255.0

Gateway

192.168.2.100


Prefered DNS

192.168.2.100

Alternate DNS

192.168.2.100

DHCP

Static


TEST RESULT


Flow Sensor Test

Passes

Functionality Test

Passes

Date

11/04/2024

Operator

ERNNY


Proteus Industries Inc. | 340 Pioneer Way, Mountain View, CA 94041 | Tel: (650) 964-4163 | Fax: (650) 965-0304